To analyze pseudo-OCV data and derive meaningful electrode models, a minimal set of metadata is required. This includes:
To analyze pseudo-OCV data and derive meaningful electrode models, a minimal set of metadata is required. This includes:


* mass loading of the active material  /  mg cm<sup>-2</sup>
* {{Template:Viewer/Link|page=Category:OSW1eeb0e2a229a43f1b197348d475067ff|url=|label=mass loading of the active material}} /  mg cm<sup>-2</sup>
* active facial electrode area  /  cm<sup>2</sup>
* active facial electrode area  /  cm<sup>2</sup>
* actual electrode coating thickness  /  µm
* {{Template:Viewer/Link|page=Category:OSW3b938708e7e44ac0a9599c04306302e7|url=|label=actual electrode coating thickness}} /  µm
* active material density  /  g cm<sup>-3</sup>
* {{Template:Viewer/Link|page=Category:OSW06448f648db643048b2ce785dba82044|url=|label=active material density}} /  g cm<sup>-3</sup>


The test temperature must also be recorded, as electrode potentials are typically temperature dependent. If the electrode is newly fabricated, its formation and cycling history should be documented to confirm stability and representative behaviour.