DirectCoulometryAtControlledPotential

Category page
Category:OSW0ecb8a448dcf514f87647aeb6bddcf39 /
Revision as of 06:04, 1 March 2025 by Admin (talk | contribs) ([bot] update of page content)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
DirectCoulometryAtControlledPotential
ID OSW0ecb8a448dcf514f87647aeb6bddcf39
UUID 0ecb8a44-8dcf-514f-8764-7aeb6bddcf39
Label DirectCoulometryAtControlledPotential
Machine compatible name DirectCoulometryAtControlledPotential
Statements (outgoing)
Statements (incoming)

Description


📎 Select files (or drop them here)... 📷 Camera
    jsondata
    rdf_type
    "owl:Class"
    uuid"0ecb8a44-8dcf-514f-8764-7aeb6bddcf39"
    iri"https://w3id.org/emmo/domain/characterisation-methodology/chameo#DirectCoulometryAtControlledPotential"
    name"DirectCoulometryAtControlledPotential"
    label
    text"DirectCoulometryAtControlledPotential"
    lang"en"
    description
    text"Coulometry at a preselected constant potential of the working electrode. Direct coulometry at controlled potential is usually carried out in convective mass trans- fer mode using a large surface working electrode. Reference and auxiliary electrodes are placed in separate compartments. The total electric charge is obtained by integration of the I–t curve or can be measured directly using a coulometer."
    lang"en"
    text"In principle, the end point at which I = 0, i.e. when the concentration of species under study becomes zero, can be reached only at infinite time. However, in practice, the electrolysis is stopped when the current has decayed to a few percent of the initial value and the charge passed at infinite time is calculated from a plot of charge Q(t) against time t. For a simple system under diffusion control Qt= Q∞[1 − exp(−DAt/Vδ)], where Q∞ = limt→∞Q(t) is the total charge passed at infinite time, D is the diffusion coefficient of the electroactive species, A the electrode area, δ the diffusion layer thickness, and V the volume of the solution."
    lang"en"
    meta
    uuid"49d52160-ee94-46bf-bb92-0f3aef050da8"
    wiki_page
    title"OSW0ecb8a448dcf514f87647aeb6bddcf39"
    namespace"Category"
    change_id
    "4caad4a3-8d2d-4691-8196-627860411931"
    type
    "Category:OSW57beed5e1294434ba77bb6516e461456"
    subclass_of
    "Category:OSW1ad8011423f15fc59ce8d8e9901452fd"
    metaclass
    "Category:OSW57beed5e1294434ba77bb6516e461456"
    imported_from"chameo:DirectCoulometryAtControlledPotential"

    This category currently contains no pages or media.

    Cookies help us deliver our services. By using our services, you agree to our use of cookies.