SampledDCPolarography

Category:OSW50997908dcb25d408f2448c140559290 /
Revision as of 06:05, 1 March 2025 by Admin (talk | contribs) ([bot] update of page content)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
SampledDCPolarography
ID OSW50997908dcb25d408f2448c140559290
UUID 50997908-dcb2-5d40-8f24-48c140559290
Label SampledDCPolarography
Machine compatible name SampledDCPolarography
Statements (outgoing)
Statements (incoming)

Description

DC polarography with current sampling at the end of each drop life mechanically enforced by a knocker at a preset drop time value. The current sampling and mechanical drop dislodge are synchronized. In this way, the ratio of faradaic current to double layer charging current is enhanced and the negative influence of charging current is partially eliminated. Due to the improved signal (faradaic current) to noise (charging current) ratio, the limit of detection is lowered.

Category (Class)
OWL Class
Imported fromA prefixed IRI defining this entry as a imported term. In OSW the prefix must be a registered imported ontology.<br>Definition: OWL Class https://w3id.org/emmo/domain/characterisation-methodology/chameo#SampledDCPolarography
EmmoClass
Supercategories<br>Definition: Category (Class), OWL Class, EmmoClass
Alternative label<br>Definition: EmmoClass
  • TASTPolarography [en]
  • metaclass<br>Definition: Category (Class), EmmoClass
  • EmmoClass
  • jsondata
    rdf_type
    "owl:Class"
    uuid"50997908-dcb2-5d40-8f24-48c140559290"
    iri"https://w3id.org/emmo/domain/characterisation-methodology/chameo#SampledDCPolarography"
    name"SampledDCPolarography"
    label
    text"SampledDCPolarography"
    lang"en"
    description
    text"DC polarography with current sampling at the end of each drop life mechanically enforced by a knocker at a preset drop time value. The current sampling and mechanical drop dislodge are synchronized. In this way, the ratio of faradaic current to double layer charging current is enhanced and the negative influence of charging current is partially eliminated. Due to the improved signal (faradaic current) to noise (charging current) ratio, the limit of detection is lowered."
    lang"en"
    meta
    uuid"b758b2cc-5ce8-4ed1-8610-e3bfc18d79dc"
    wiki_page
    title"OSW50997908dcb25d408f2448c140559290"
    namespace"Category"
    change_id
    "4caad4a3-8d2d-4691-8196-627860411931"
    type
    "Category:OSW57beed5e1294434ba77bb6516e461456"
    subclass_of
    "Category:OSW755624b1cd1c517fa350252ce0e07bd1"
    metaclass
    "Category:OSW57beed5e1294434ba77bb6516e461456"
    imported_from"chameo:SampledDCPolarography"
    altLabel
    text"TASTPolarography"
    lang"en"

    This category currently contains no pages or media.