ConductometricTitration

Category:OSWbc4ff12dd91f5dd7be30bbeba8048b61
ConductometricTitration
ID OSWbc4ff12dd91f5dd7be30bbeba8048b61
UUID bc4ff12d-d91f-5dd7-be30-bbeba8048b61
Label ConductometricTitration
Machine compatible name ConductometricTitration
Statements (outgoing)
Statements (incoming)

Description

Titration in which the electric conductivity of a solution is measured as a function of the amount of titrant added. The equivalence-point is obtained as the intersection of linear parts of the conductance G, versus titrant volume V, curve. The method can be used for deeply coloured or turbid solutions. Acid-base and precipitation reactions are most frequently used. The method is based on replacing an ionic species of the analyte with another species, cor- responding to the titrant or the product with significantly different conductance.

Category (Class)
OWL Class
Imported fromA prefixed IRI defining this entry as a imported term. In OSW the prefix must be a registered imported ontology.<br>Definition: OWL Class https://w3id.org/emmo/domain/characterisation-methodology/chameo#ConductometricTitration
EmmoClass
Supercategories<br>Definition: Category (Class), OWL Class, EmmoClass
metaclass<br>Definition: Category (Class), EmmoClass
  • EmmoClass
  • jsondata
    rdf_type
    "owl:Class"
    uuid"bc4ff12d-d91f-5dd7-be30-bbeba8048b61"
    iri"https://w3id.org/emmo/domain/characterisation-methodology/chameo#ConductometricTitration"
    name"ConductometricTitration"
    label
    text"ConductometricTitration"
    lang"en"
    description
    text"Titration in which the electric conductivity of a solution is measured as a function of the amount of titrant added. The equivalence-point is obtained as the intersection of linear parts of the conductance G, versus titrant volume V, curve. The method can be used for deeply coloured or turbid solutions. Acid-base and precipitation reactions are most frequently used. The method is based on replacing an ionic species of the analyte with another species, cor- responding to the titrant or the product with significantly different conductance."
    lang"en"
    meta
    uuid"499d6b75-5c98-4c04-82a6-524069bcaae9"
    wiki_page
    title"OSWbc4ff12dd91f5dd7be30bbeba8048b61"
    namespace"Category"
    change_id
    "4caad4a3-8d2d-4691-8196-627860411931"
    type
    "Category:OSW57beed5e1294434ba77bb6516e461456"
    subclass_of
    "Category:OSWda8409362c2c5606a64b9e2bbf3c1ae4"
    metaclass
    "Category:OSW57beed5e1294434ba77bb6516e461456"
    imported_from"chameo:ConductometricTitration"

    This category currently contains no pages or media.